Thursday, September 30, 2010

Upcoming Plugfests

Heads' up: Deadlines for the B.I. autumn plugfest November 16-18 in Atlanta are a couple weeks away.
BIG-EU's spring plugfest is tentatively set for May 9-13, 2011, possibly in either Vienna, Austria or Dortmund, Germany. More as it develops.

Hope to see you there.

Update: Looks like it will be in Saarbrücken.

Facility Decision's Leaders of the Pack awards

Well, this should be a fun event! I received an e-mail announcing Facility Decisions' Monday evening reception AND BACnet International's Leaders of the Pack award ceremony Tuesday (Oct. 5, Exhibit Hall, 3:30 PM). The awards and descriptions are as follows (click on the image for larger version):

Oh darn. I vaguely remember receiving an e-mail about nominations, but it came at a time when my Inbox was overflowing daily with Smart Grid e-mails. I wonder if I can find it in order to nominate David Fisher for the Rottweiler Award.

Wednesday, September 29, 2010

Addendum on the Luce(rne)

Shortly after the exchanges noted in the preceding posting, I received the folloowing e-mail with a photo from our dinner cruise last week:

Hi Bill,

have to say that no addendum gets lost because of you.... but what the heck, what addendum were you shooting?

Regards,
/Teemu


Well, Teemu, I'd like to say it was the latest effort to "socialize" new proposed changes to the BACnet standard, something like this proposed Addendum 135-2008ag:


But I won't.

The Hazard of Change

To borrow a term I hear a lot in the Smart Grid world, it seems those of us on the BACnet Committee aren't doing enough to "socialize" changes, mostly additions, to the standard. This became clear today with an exchange today on the BACNET-L email list.

John Arwine (just a short ways down the road from here) noted that he was working witha new BACnet controller, one of the first BACnet devices from its manufacturer. The documentation for the device identified it as having Analog Variables, Digital Variables, and Integer Variables. He hadn't heard of the last and asked the list whether this was a defined BACnet object type.

I responded:

Yes. If you look at Addendum 135-2008w (http://www.ashrae.org/technology/page/20), you will find:
12.G Integer Value Object Type
12.H Positive Integer Value Object Type

This was published early this year.

And it was. It didn't take me long to dig out a copy of the addendum because I knew what I was looking for, even though I no longer keep all the BACnet addenda letters and their contents mentally correlated.

With 33 addenda, Addendum a currently through through ag, and many of them coompilations of miscellaneous unrelated changes, it gets difficult -- especially when I'm putting in a LOT more time these days on work on the Smart Grid than on BACnet.

But at least I knew where to turn and what to look for. The description of the contents of Addendum w is unusually terse, both in the addendum and on the web page, saying only "135-2008w-1. Add more primitive value objects, p. 2." This could be easy to miss if one were looking for "Integer Variables."

So we're making these additions, but not getting the information out to our users as well as we should. This is not a good thing.

---

Committee chair Dave Robin had a good response too (sparing me the necessityof a followup, thank you Dave!), noting that the terminology being used by the manufacturer was nonstandard. For many BACnet oldtimers the use of "unofficial" terminology provides a warning that something might be misinterpreted.

Quite possible in this case where a "Integer Variable" might be a new Integer Value or Positive Integer Value object, or it could be a Multi-state Value object.

So now John has a new task, to find out which of these object is intended -- if it's not a proprietary object!

Tuesday, September 28, 2010

How to read large BACnet Arrays

There's some very active discussion going on in the BACNET-L mailing list about how to read arrays that are too large to fit in a single APDU when segmentation isn't supported. The solution, as Frank Schubert pointed out this morning, is to be found in the BTL Implementation Guidelines (for download), to wit:

3.4 Be prepared to read the Object_List array element by element

Some small devices that do not support segmentation have Object_List properties that are too large to transmit unsegmented. If a device needs to read another’s Object_List property, be prepared to read it array element by array element.

This could be a little slow for clients reading the Object_List of devices with thousands of aobjects, however. There was discussion of a proposal before the committee to use ReadRange to read the array in "chunks", rather a bit less tedious, but a little quick research revealed that the committee tabled that proposal (vote: 1-8-4) in the spring meeting last May.

But the initial question that started this discussion posed a thornier problem: a physical access control device with hundreds of thousands of objects. Even segmentation will not help here because the segmentation counter would have to wrap. (Perhaps someone can research the language change that would allow that to occur?)

Reading the Object_List of one of these devices, array element by array element, would take quite some time. Using ReadPropertyMultiple to read by "chunks" would seem to be the best available solution at this time. At least unless and until the tabled proposal is brought back up.

(Note to implementers of such large server devices: be sure you can locate the last element of the Object_List quickly -- I have seen implementations fail to respond to such read requests before the client timed out because the server's linear search algorithm took too long.)

Monday, September 27, 2010

Didn't get the memo

Back when I began this blog, Marketing thought it would be a good idea to add a little bit of "social networking" along with it and suggested I sign up on Twitter (and CoTweet.com, because the corporate firewall blocked Twitter), despite my protestations that "Swans don't tweet!"

Often when I posted on this blog, particularly for technical matters, I would sent out a (co)tweet right away -- the Marketing folks loved it.

But no more. Now the corporate firewall also blocks CoTweet. I wonder how long until Hmmmm hm hmmmmm meets the same fate; I guess IT didn't get the memo that some of this activity is corporately sanctioned. Or maybe it isn't official enough.

Oops: Turns out IT didn't do a thing. Some(?) of the firewall is "externally" managed and they were the ones to re-brand CoTweet. One of our IT folks checked the log for this month -- two accesses (one successful, one not) so we don't have a usage problem. And I am betting both accesses were mine. Now working with IT to get access.

Friday, September 24, 2010

Awright, who's the wag?!?

It's long been customary in the Alerton facility that if you're going to be away during regular work days you leave a Post-It note on your door stating, at a minimum, when you intend to return to the office. I usually leave more but because I had multiple destinations I just left a note saying, "Back 9/23."

When I returned I discovered that somebody had modified my note to read "Bac 9/23."

Very funny.

[For the non-native-English-speaking readers of this blog, the title is American slang for "All right, who's the joker?]"

Update: I suspected Johnny, but it turned out to be Dean.